public interface Pdh extends StdCallLibrary
Modifier and Type | Interface and Description |
---|---|
static class |
Pdh.PDH_COUNTER_PATH_ELEMENTS
Components of a counter path
|
static class |
Pdh.PDH_RAW_COUNTER
The data as it was collected from the counter provider.
|
static class |
Pdh.PDH_TIME_INFO
Information on time intervals as applied to the sampling of performance data.
|
StdCallLibrary.StdCallCallback
Library.Handler
Modifier and Type | Field and Description |
---|---|
static Pdh |
INSTANCE |
static int |
PDH_CSTATUS_NO_MACHINE |
static int |
PDH_CSTATUS_NO_OBJECT |
static int |
PDH_CVERSION_WIN40 |
static int |
PDH_CVERSION_WIN50 |
static int |
PDH_FMT_1000 |
static int |
PDH_FMT_ANSI |
static int |
PDH_FMT_DOUBLE |
static int |
PDH_FMT_LARGE |
static int |
PDH_FMT_LONG |
static int |
PDH_FMT_NOCAP100 |
static int |
PDH_FMT_NODATA |
static int |
PDH_FMT_NOSCALE |
static int |
PDH_FMT_RAW |
static int |
PDH_FMT_UNICODE |
static int |
PDH_INSUFFICIENT_BUFFER |
static int |
PDH_INVALID_ARGUMENT |
static int |
PDH_MAX_COUNTER_NAME
Maximum counter name length.
|
static int |
PDH_MAX_COUNTER_PATH
Maximum full counter path length.
|
static int |
PDH_MAX_DATASOURCE_PATH
Maximum full counter log name length.
|
static int |
PDH_MAX_INSTANCE_NAME
Maximum counter instance name length.
|
static int |
PDH_MEMORY_ALLOCATION_FAILURE |
static int |
PDH_MORE_DATA |
static int |
PDH_PATH_WBEM_INPUT |
static int |
PDH_PATH_WBEM_RESULT |
static int |
PDH_VERSION |
static int |
PERF_DETAIL_COSTLY |
static int |
PERF_DETAIL_STANDARD |
FUNCTION_MAPPER, STDCALL_CONVENTION
OPTION_ALLOW_OBJECTS, OPTION_CALLING_CONVENTION, OPTION_CLASSLOADER, OPTION_FUNCTION_MAPPER, OPTION_INVOCATION_MAPPER, OPTION_OPEN_FLAGS, OPTION_STRING_ENCODING, OPTION_STRUCTURE_ALIGNMENT, OPTION_TYPE_MAPPER
Modifier and Type | Method and Description |
---|---|
int |
PdhAddCounter(WinNT.HANDLE hQuery,
java.lang.String szFullCounterPath,
BaseTSD.DWORD_PTR dwUserData,
WinNT.HANDLEByReference phCounter)
Adds the specified counter to the query.
|
int |
PdhAddEnglishCounter(WinNT.HANDLE hQuery,
java.lang.String szFullCounterPath,
BaseTSD.DWORD_PTR dwUserData,
WinNT.HANDLEByReference phCounter) |
int |
PdhCloseQuery(WinNT.HANDLE hQuery)
Closes all counters contained in the specified query, closes all
handles related to the query, and frees all memory associated with
the query.
|
int |
PdhCollectQueryData(WinNT.HANDLE hQuery)
Collects the current raw data value for all counters in the specified
query and updates the status code of each counter.
|
int |
PdhCollectQueryDataEx(WinNT.HANDLE hQuery,
int dwIntervalTime,
WinNT.HANDLE hNewDataEvent)
Uses a separate thread to collect the current raw data value for all counters
in the specified query.
|
int |
PdhCollectQueryDataWithTime(WinNT.HANDLE hQuery,
WinDef.LONGLONGByReference pllTimeStamp)
Collects the current raw data value for all counters in the specified
query and updates the status code of each counter.
|
int |
PdhConnectMachine(java.lang.String szMachineName)
Connects to the specified computer.
|
int |
PdhEnumObjectItems(java.lang.String szDataSource,
java.lang.String szMachineName,
java.lang.String szObjectName,
Pointer mszCounterList,
WinDef.DWORDByReference pcchCounterListLength,
Pointer mszInstanceList,
WinDef.DWORDByReference pcchInstanceListLength,
int dwDetailLevel,
int dwFlags)
Returns the specified object's counter and instance names that exist on
the specified computer or in the specified log file.
|
int |
PdhGetDllVersion(WinDef.DWORDByReference lpdwVersion)
Returns the version of the currently installed Pdh.dll file.
|
int |
PdhGetRawCounterValue(WinNT.HANDLE hCounter,
WinDef.DWORDByReference lpdwType,
Pdh.PDH_RAW_COUNTER pValue) |
int |
PdhLookupPerfIndexByName(java.lang.String szMachineName,
java.lang.String szNameBuffer,
WinDef.DWORDByReference pdwIndex)
Returns the counter index corresponding to the specified counter name.
|
int |
PdhLookupPerfNameByIndex(java.lang.String szMachineName,
int dwNameIndex,
Pointer szNameBuffer,
WinDef.DWORDByReference pcchNameBufferSize)
Returns the performance object name or counter name corresponding to the
specified index.
|
int |
PdhMakeCounterPath(Pdh.PDH_COUNTER_PATH_ELEMENTS pCounterPathElements,
char[] szFullPathBuffer,
WinDef.DWORDByReference pcchBufferSize,
int dwFlags)
Creates a full counter path using the members specified in the
Pdh.PDH_COUNTER_PATH_ELEMENTS structure. |
int |
PdhOpenQuery(java.lang.String szDataSource,
BaseTSD.DWORD_PTR dwUserData,
WinNT.HANDLEByReference phQuery)
Creates a new query that is used to manage the collection of performance data.
|
int |
PdhRemoveCounter(WinNT.HANDLE hCounter)
Removes a counter from a query.
|
int |
PdhSetQueryTimeRange(WinNT.HANDLE hQuery,
Pdh.PDH_TIME_INFO pInfo) |
int |
PdhValidatePath(java.lang.String szFullCounterPath)
Validates that the counter is present on the computer specified in the counter path.
|
static final Pdh INSTANCE
static final int PDH_MAX_COUNTER_NAME
static final int PDH_MAX_INSTANCE_NAME
static final int PDH_MAX_COUNTER_PATH
static final int PDH_MAX_DATASOURCE_PATH
static final int PDH_MORE_DATA
static final int PDH_INSUFFICIENT_BUFFER
static final int PDH_INVALID_ARGUMENT
static final int PDH_MEMORY_ALLOCATION_FAILURE
static final int PDH_CSTATUS_NO_MACHINE
static final int PDH_CSTATUS_NO_OBJECT
static final int PDH_CVERSION_WIN40
static final int PDH_CVERSION_WIN50
static final int PDH_VERSION
static final int PDH_PATH_WBEM_RESULT
static final int PDH_PATH_WBEM_INPUT
static final int PDH_FMT_RAW
static final int PDH_FMT_ANSI
static final int PDH_FMT_UNICODE
static final int PDH_FMT_LONG
static final int PDH_FMT_DOUBLE
static final int PDH_FMT_LARGE
static final int PDH_FMT_NOSCALE
static final int PDH_FMT_1000
static final int PDH_FMT_NODATA
static final int PDH_FMT_NOCAP100
static final int PERF_DETAIL_COSTLY
static final int PERF_DETAIL_STANDARD
int PdhConnectMachine(java.lang.String szMachineName)
szMachineName
- The name of the computer to connect to. If
null
, PDH connects to the local computer.int PdhGetDllVersion(WinDef.DWORDByReference lpdwVersion)
lpdwVersion
- A variable that receives the version of Pdh.dll.int PdhOpenQuery(java.lang.String szDataSource, BaseTSD.DWORD_PTR dwUserData, WinNT.HANDLEByReference phQuery)
szDataSource
- The name of the log file from which to retrieve performance data.
If null
, performance data is collected from a real-time data source.dwUserData
- User-defined value to associate with this query.phQuery
- (Out) Handle to the query. You use this handle in subsequent calls.int PdhCloseQuery(WinNT.HANDLE hQuery)
hQuery
- Handle to the query to close.int PdhMakeCounterPath(Pdh.PDH_COUNTER_PATH_ELEMENTS pCounterPathElements, char[] szFullPathBuffer, WinDef.DWORDByReference pcchBufferSize, int dwFlags)
Pdh.PDH_COUNTER_PATH_ELEMENTS
structure.pCounterPathElements
- Structure that contains the members
used to make up the pathszFullPathBuffer
- Caller-allocated buffer that receives a null-terminated
counter path. The maximum length of a counter path is PDH_MAX_COUNTER_PATH.
Set to null
if pcchBufferSize is zero.pcchBufferSize
- Size of the szFullPathBuffer buffer. If
zero on input, the function returns PDH_MORE_DATA and sets this parameter
to the required buffer size. If the buffer is larger than the required
size, the function sets this parameter to the actual size of the buffer
that was used.dwFlags
- Format of the input and output counter values.int PdhAddCounter(WinNT.HANDLE hQuery, java.lang.String szFullCounterPath, BaseTSD.DWORD_PTR dwUserData, WinNT.HANDLEByReference phCounter)
hQuery
- Handle to the query to which you want to add the counter.szFullCounterPath
- String that contains the counter path.
The maximum length of a counter path is PDH_MAX_COUNTER_PATH
.dwUserData
- User-defined value.phCounter
- (Out) Handle to the counter that was added to the query.int PdhAddEnglishCounter(WinNT.HANDLE hQuery, java.lang.String szFullCounterPath, BaseTSD.DWORD_PTR dwUserData, WinNT.HANDLEByReference phCounter)
int PdhRemoveCounter(WinNT.HANDLE hCounter)
hCounter
- Handle of the counter to remove from its query.int PdhGetRawCounterValue(WinNT.HANDLE hCounter, WinDef.DWORDByReference lpdwType, Pdh.PDH_RAW_COUNTER pValue)
hCounter
- Handle of the counter from which to retrieve the current raw value.lpdwType
- Receives the counter type - this parameter is optionalpValue
- The Pdh.PDH_RAW_COUNTER
structure to receive the dataint PdhValidatePath(java.lang.String szFullCounterPath)
szFullCounterPath
- The counter path to validateint PdhCollectQueryData(WinNT.HANDLE hQuery)
hQuery
- Handle to the queryint PdhCollectQueryDataEx(WinNT.HANDLE hQuery, int dwIntervalTime, WinNT.HANDLE hNewDataEvent)
hQuery
- Handle to the querydwIntervalTime
- Time interval to wait, in seconds.hNewDataEvent
- Handle to the event that you want PDH to signal after
the time interval expires. To create an event object, call the
Kernel32.CreateEvent(com.sun.jna.platform.win32.WinBase.SECURITY_ATTRIBUTES, boolean, boolean, String)
functionint PdhCollectQueryDataWithTime(WinNT.HANDLE hQuery, WinDef.LONGLONGByReference pllTimeStamp)
hQuery
- Handle to the querypllTimeStamp
- Time stamp when the first counter value in the query
was retrieved. The time is specified as WinBase.FILETIME
.int PdhSetQueryTimeRange(WinNT.HANDLE hQuery, Pdh.PDH_TIME_INFO pInfo)
hQuery
- Handle to the query.pInfo
- A Pdh.PDH_TIME_INFO
structure that specifies the time range.int PdhEnumObjectItems(java.lang.String szDataSource, java.lang.String szMachineName, java.lang.String szObjectName, Pointer mszCounterList, WinDef.DWORDByReference pcchCounterListLength, Pointer mszInstanceList, WinDef.DWORDByReference pcchInstanceListLength, int dwDetailLevel, int dwFlags)
szDataSource
- String that specifies the name of the log file used to
enumerate the counter and instance names. If NULL, the
function uses the computer specified in the szMachineName
parameter to enumerate the names.szMachineName
- String that specifies the name of the computer that contains
the counter and instance names that you want to enumerate.
Include the leading slashes in the computer name, for example,
\\computername. If the szDataSource parameter is NULL, you can
set szMachineName to NULL to specify the local computer.szObjectName
- String that specifies the name of the object whose counter and
instance names you want to enumerate.mszCounterList
- Caller-allocated buffer that receives a list of
null-terminated counter names provided by the specified
object. The list contains unique counter names. The list is
terminated by two NULL characters. Set to NULL if the
pcchCounterListLengthparameter is zero.pcchCounterListLength
- Size of the mszCounterList buffer, in TCHARs. If zero on input
and the object exists, the function returns PDH_MORE_DATA and
sets this parameter to the required buffer size. If the buffer
is larger than the required size, the function sets this
parameter to the actual size of the buffer that was used. If
the specified size on input is greater than zero but less than
the required size, you should not rely on the returned size to
reallocate the buffer.mszInstanceList
- Caller-allocated buffer that receives a list of
null-terminated instance names provided by the specified
object. The list contains unique instance names. The list is
terminated by two NULL characters. Set to NULL if
pcchInstanceListLength is zero.pcchInstanceListLength
- Size of the mszInstanceList buffer, in TCHARs. If zero on
input and the object exists, the function returns
PDH_MORE_DATA and sets this parameter to the required buffer
size. If the buffer is larger than the required size, the
function sets this parameter to the actual size of the buffer
that was used. If the specified size on input is greater than
zero but less than the required size, you should not rely on
the returned size to reallocate the buffer. If the specified
object does not support variable instances, then the returned
value will be zero. If the specified object does support
variable instances, but does not currently have any instances,
then the value returned is 2, which is the size of an empty
MULTI_SZ list string.dwDetailLevel
- Detail level of the performance items to return. All items
that are of the specified detail level or less will be
returned.dwFlags
- This parameter must be zero.int PdhLookupPerfIndexByName(java.lang.String szMachineName, java.lang.String szNameBuffer, WinDef.DWORDByReference pdwIndex)
szMachineName
- Null-terminated string that specifies the name of the computer
where the specified counter is located. The computer name can
be specified by the DNS name or the IP address. If NULL, the
function uses the local computer.szNameBuffer
- Null-terminated string that contains the counter name.pdwIndex
- Index of the counter.int PdhLookupPerfNameByIndex(java.lang.String szMachineName, int dwNameIndex, Pointer szNameBuffer, WinDef.DWORDByReference pcchNameBufferSize)
szMachineName
- Null-terminated string that specifies the name of the computer
where the specified performance object or counter is located.
The computer name can be specified by the DNS name or the IP
address. If NULL, the function uses the local computer.dwNameIndex
- Index of the performance object or counter.szNameBuffer
- Caller-allocated buffer that receives the null-terminated name
of the performance object or counter. Set to NULL if
pcchNameBufferSize is zero.pcchNameBufferSize
- Size of the szNameBuffer buffer, in TCHARs. If zero on input,
the function returns PDH_MORE_DATA and sets this parameter to
the required buffer size. If the buffer is larger than the
required size, the function sets this parameter to the actual
size of the buffer that was used. If the specified size on
input is greater than zero but less than the required size,
you should not rely on the returned size to reallocate the
buffer.